Evaluation of partial carbon dioxide rebreathing cardiac output measurement during thoracic surgery
Ju-Mei Ng1, Mark Y Chow, Pierre C Ip-Yam
1Department of Anaesthesia and Surgical Intensive Care, Singapore General Hospital, Singapore. jng1@partners.org
Objective:
Noninvasive partial CO2 rebreathing (NICO; Novametrix Medical Systems, Inc, Wallingford, CT) is a relatively new alternative to thermodilution (TDCO) for measurement of cardiac output. This study compares the 2 methods during thoracic surgery and one-lung ventilation.
Design:
A prospective, observational study.
Setting:
A tertiary hospital.
Participants:
Twelve adult patients undergoing elective thoracotomy and one-lung ventilation in the lateral decubitus position.
Interventions:
Paired measurements of cardiac output were performed during (1) 2-lung ventilation in the supine position (postinduction of anesthesia), (2) 10 minutes after initiation of one-lung ventilation in the lateral decubitus position with the nondependent chest open, and (3) after 30 minutes on one-lung ventilation. An average of 3 consecutive (10 mL 20 degrees C saline) TDCO measurements made during end-expiration was compared with corresponding NICO measurements.
Measurements And Main Results:
The NICO showed a tendency to underestimate cardiac output compared with TDCO at all measurement times. Overall, bias was -0.29 L/min and limits of agreement -1.69 to 1.43 L/min.
Conclusions:
There was a moderate agreement between cardiac output measurements obtained with the NICO and TDCO. The present data suggest that the NICO technique may be useful during thoracic surgery.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: