Related Experiment Video
Updated: Jul 11, 2026

Microelectrode Array Recording of Sinoatrial Node Firing Rate to Identify Intrinsic Cardiac Pacemaking Defects in Mice
Published on: July 5, 2021
Autonomic control and innervation of the atrioventricular junctional pacemaker
William J Hucker1, Vladimir P Nikolski, Igor R Efimov
1Department of Biomedical Engineering, Washington University, One Brookings Drive, St. Louis, MO 63130, USA.
Background:
The main physiologic function of the AV junction is control of timing between atrial and ventricular excitation. However, under pathologic conditions, the AV junction may become the pacemaker of the heart. Unlike the well-characterized sinoatrial node (SAN), autonomic control of the AV junctional pacemaker has not been studied.
Objective:
The purpose of this study was to characterize the autonomic control and innervation of the AV junctional pacemaker.
Methods:
The response of rabbit AV junctional pacemaker to autonomic stimulation was investigated using optical mapping, autonomic modulation via subthreshold stimulation (n = 12), and quantitative immunohistochemistry (n = 5), and the density of parasympathetic and sympathetic innervation in optically mapped preparations was quantified.
Results:
Subthreshold stimulation applied adjacent to the conduction system in the triangle of Koch autonomically modulates the junctional rate, and parasympathetic and sympathetic components can be separated with atropine and the beta-blocker nadolol. Subthreshold stimulation increased the rate maximally to 2.1 +/- 0.4 times when applied with atropine. Unlike the SAN pacemaker, which shifts significantly in response to autonomic stimulation, the AV junctional pacemaker remains stationary (most often in the inferior nodal extension), moving in only 5% of subthreshold stimulation trials. Staining with tyrosine hydroxylase and choline acetyltransferase revealed heterogeneous innervation within the AV junction.
Conclusion:
AV junctional rhythm can be autonomically modulated with subthreshold stimulation to produce junctional rates of 145 +/- 16 bpm (cycle length 412 +/- 29 ms), similar to sinus rates in rabbit. Unlike the SAN, the anatomic location of the AV junctional pacemaker is stable during autonomic modulation.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Electrophysiology of Normal Cardiac Rhythm
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Mechanism of Cardiac Arrhythmias
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and empty blood into the...

