Related Experiment Video
Updated: Jul 11, 2026

Intra-cardiac Side-Firing Light Catheter for Monitoring Cellular Metabolism using Transmural Absorbance Spectroscopy of Perfused Mammalian Hearts
Published on: May 12, 2019
Accurate myoglobin oxygen saturation by optical spectroscopy measured in blood-perfused rat muscle
Lorilee S L Arakaki1, David H Burns, Martin J Kushmerick
1Department of Bioengineering, University of Washington, Seattle, WA 98195, USA.
Abstract:
Optical spectra were acquired from myoglobin and hemoglobin solutions and from the tibialis anterior muscle of Sprague-Dawley rats in the visible region (515 to 660 nm). Validation studies were performed on the in vitro spectra to demonstrate that partial least squares analysis of second-derivative spectra yields accurate measurements of myoglobin saturation in the presence of varying hemoglobin concentrations and saturations. When hemoglobin concentrations were varied between 0.25 and 4 times that of myoglobin, myoglobin saturations were measured with a root mean squared error (RMSE) of 4.9% (n = 56) over the full range from 0 to 1. Myoglobin saturations were also shown to be largely unaffected by hemoglobin saturation. RMSE values of only 1.7% (n = 77) were found when hemoglobin saturations were varied independently from myoglobin saturations. These in vitro validation studies represent the most complete and rigorous done to date using partial least squares analysis on myoglobin and hemoglobin spectra. Analysis of reflectance spectra from the rat hind limb yielded accurate measures of volume-averaged myoglobin fractional saturation in the presence of hemoglobin in vivo. Hemodilution showed that myoglobin fractional saturation measurements in the rat leg are not sensitive to changes in hematocrit, thereby confirming the results from solutions in vitro. Decreases in optical density of 11.3 +/- 3.0% (n = 3) were achieved while myoglobin saturation decreased by only 3.1 +/- 3.8%. Myoglobin saturation was significantly increased when the fraction of inspired O(2) was increased, showing that manipulations of myoglobin saturation are detectable and that myoglobin is not fully saturated in resting muscle. Together, these in vitro and in vivo studies show that cellular oxygenation derived from myoglobin fractional saturation can be measured accurately with little cross-talk from hemoglobin in the visible wavelength region, thereby extending optical spectroscopic studies of cellular and vascular oxygenation beyond the near-infrared regions previously studied.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...