Related Experiment Video
Updated: Jul 11, 2026

06:35
Ultrasound Assessment of Endothelial Function: A Technical Guideline of the Flow-mediated Dilation Test
Published on: April 27, 2016
Practice guideline for the performance of physiologic evaluation of extremity arteries
Raymond E Bertino1, Clement J Grassi, Edward I Bluth
1clement.grassi@med.va.gov
Journal of Vascular and Interventional Radiology : JVIR
|October 4, 2007
Abstract
No abstract available in PubMed .
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Clinical manifestationsPeripheral Arterial Disease (PAD) manifests through a range of symptoms, from the characteristic intermittent claudication to atypical presentations and severe complications in advanced stages. Intermittent claudication, a hallmark symptom of PAD, presents as exercise-induced muscle pain that typically resolves within minutes of rest. This pain is reproducible and stems from inadequate blood flow, leading to the accumulation of lactic acid produced during anaerobic...
Assessment of the Cardiovascular System III: Palpation
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of blood pressure in brachial artery(one-step method)
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Blood pressure in the Leg
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:

