Related Experiment Video
Updated: Jul 11, 2026

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
Published on: March 12, 2021
Three-dimensional spin-lock magnetic resonance imaging of the shoulder joint at 3 T: initial experience
Renata La Rocca Vieira1, Sait Kubilay Pakin, Conrado Furtado de Albuquerque Cavalcanti
1Radiology Department, NYU Hospital for Joint Diseases, New York University School of Medicine, New York, NY, USA. relarocca@gmail.com
Objectives:
This was a pilot study which aimed to assess the feasibility of 3D-spin-lock (3D-T(1rho)) MRI of the shoulder joint and to establish baseline values of healthy humeral and glenoid cartilages in vivo.
Material And Methods:
Four asymptomatic volunteers [mean age 31 years (range 29-36 years)] were recruited. A 3.0 T scanner, employing a four-channel, phased-array, shoulder, radio-frequency (RF) coil was used. Three-dimensional T(1rho)-weighted images were acquired with a 3D gradient-echo (GRE) sequence with T(1rho) magnetization preparation. In order to a construct T(1rho) map, we acquired four 3D-T(1rho)-weighted images with spin-locking length (TSL) values of 2 ms, 10 ms, 20 ms, and 30 ms. The glenoid and humeral cartilage were segmented manually at each slice of the 3D images. We performed additional regional analysis by dividing the cartilage into anterior/posterior and superior/inferior regions.
Results:
The global average T(1rho) value of the shoulder cartilages varied from 37.9 ms to 48.5 ms and from 32.4 ms to 36.9 ms for humeral and glenoid cartilages, respectively. In the humeral cartilage, the average regional T(1rho) values varied from 35.9 ms to 52.2 ms; 54.4 ms to 69.0 ms; 39.1 ms to 49.3 ms and 34.6 ms to 57.2 ms for the anterior-superior, anterior-inferior , posterior-superior and posterior-inferior regions, respectively. In the glenoid cartilage, the values varied from 31.3 ms to 40.8 ms; 34.1 ms to 35.3 ms; 26.7 ms to 37.2 ms and 32.8 ms to 35.7 ms for the same regions, respectively.
Conclusion:
We demonstrated that 3D-T(1rho) MRI of the shoulder can be performed on a 3 T clinical scanner within specific absorption rate (SAR) limits, and we present baseline values for healthy patients which may be useful for quantitative comparison with diseased shoulders.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Atomic Nuclei: Magnetic Resonance
NMR Spectroscopy: Spin–Spin Coupling

