Abstract:
The aim of the in vitro study was to evaluate the decontamination potential of common antiseptic solutions for heat-sensitive implantological drill guide templates. One hundred implantologists were evaluated on the basis of a questionnaire for their measures of disinfection. On the basis of these results, 80% alcohol, Octenidine 0.1%, and Chlorhexidine 0.12% were tested in an in vitro model for their decontamination efficacy for heat-sensitive plastic material infected with Pseudomonas aeruginosa, Acinetobacter baumannii, Enterococcus faecalis, Enterococcus faecium, Staphylococcus aureus, Enterobacter cloacae, Escherichia coli, and Candida albicans. The microorganisms were selected on the basis of results of environmental testing of dental laboratories. The results of the questionnaire revealed that Chlorhexidine was used by 30%, 80% alcohol by 23%, and Octenidine by 7% of the dentists. Using the in vitro model, with the exception of S. aureus, Chlorhexidine was not able to completely eliminate the microorganisms after 15 min of application. In contrast, the treatment with Octenidine revealed no further growth of the tested microorganisms after that time. The 80% alcohol was more efficient. No growth of microorganisms could be detected in any of the tests after 5 min of incubation. On the basis of our results and due to the fact that suitable installations for sterilization were hardly used by the dental practitioners, the disinfection of templates should be preferentially performed with 80% alcohol or Octenidine using an incubation time of 15 min with ultrasonication.
Related Concept Videos
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...