Fiber optic-linear array detection spectrophotometry in combination with cloud point extraction for simultaneous
N Shokoufi1, F Shemirani, F Memarzadeh
1Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, The University of Tehran, P.O. Box 14155-6455, Tehran, Iran.
Abstract:
A new combined method including fiber optic-linear array detection spectrophotometry (FO-LADS) and cloud point extraction (CPE) was developed using a cylindrical micro cell for simultaneous preconcentration and determination of different species. The CPE and FO-LADS methods have good matching conditions for combination because FO-LADS is suitable as a detection technique for the low volume of remained phase obtained after CPE. This combination was carried out using 50 microL cylindrical micro cell and then employed for simultaneous preconcentration and determination of cobalt and nickel. Cloud point extraction method was based on the chromogenic reaction of metal ions and 1-(2-pyridylazo)-2-naphthol (PAN) and then preconcentration of formed complexes using octylphenoxypolyethoxyethanol (Triton X-114). The remained phase after CPE was transferred into cylindrical micro cell and located at the cell holder of FO-LADS. The spectra of cobalt and nickel complexes were collected by FO-LADS and processed for ordinary and first derivative spectrophotometry. Optimization of different parameters was evaluated. Under optimum conditions, calibration curves were linear in the range of 0.6-30.0 and 0.1-15.0 microg L(-1) with detection limits of 0.2 and 0.04 microg L(-1) for Co and Ni respectively. The relative standard deviations (R.S.D.s) were lower than 4%. The obtained enhancement factors were 198 and 199 for cobalt and nickel, respectively. The proposed method was compared with the other methods and applied to the analysis of several real and spiked samples.
More Related Videos
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
