Related Experiment Video
Updated: Jul 11, 2026

Characterization of Thymus-dependent and Thymus-independent Immunoglobulin Isotype Responses in Mice Using Enzyme-linked Immunosorbent Assay
Published on: September 7, 2018
Development of ELISAs for quantification of HMFG1-specific human anti-mouse IgG and IgM antibodies
A L M Oei1, O C Boerman, A Geurts-Moespot
1Department of Obstetrics and Gynecology, Radboud University Nijmegen Medical Center, 6500 HB Nijmegen, The Netherlands. A.Oei@obgyn.umcn.nl
The aim of this study was to develop and validate ELISAs for quantification of HAMA-IgM and HAMA-IgG in serum of patients with ovarian cancer who enrolled in a large international randomized phase III trial of intraperitoneal Yttrium-90-labeled HMFG1 murine monoclonal antibody therapy. The capture antibody of these 2 assays was the murine antibody HMFG1, while mouse anti-human IgM-HRP or mouse anti-human IgG(Fc)-HRP served as tracer antibodies. A pool of HAMA-positive serum samples was used to prepare a series of assay standards and another pool served as reference preparation. The analytical sensitivity of the HAMA-IgM assay was 2.5 arbitrary units per mL (AU/mL) and 4.7 AU/mL for the HAMA-IgG ELISA. Diluted serum samples showed good parallelism with the HAMA-IgM and HAMA-IgG standard dose-response curves. Within-assay coefficient of variation was 7.5% for HAMA-IgM and 6.5% for HAMA-IgG. Between-assay variation was 14.2% for HAMA-IgM and 15.3% for HAMA-IgG. The developed HAMA-IgM and HAMA-IgG ELISAs show satisfactory reliability criteria (sensitivity, parallelism and precision) and are suitable for monitoring of HAMA-IgM and HAMA-IgG responses in ovarian cancer patients. These ELISAs will be used to monitor the development of HAMAs in patients who received radioimmunotherapy with murine HMFG1.
The aim of this study was to develop and validate ELISAs for quantification of HAMA-IgM and HAMA-IgG in serum of patients with ovarian cancer who enrolled in a large international randomized phase III trial of intraperitoneal Yttrium-90-labeled HMFG1 murine monoclonal antibody therapy. The capture antibody of these 2 assays was the murine antibody HMFG1, while mouse anti-human IgM-HRP or mouse anti-human IgG(Fc)-HRP served as tracer antibodies. A pool of HAMA-positive serum samples was used to prepare a series of assay standards and another pool served as reference preparation. The analytical sensitivity of the HAMA-IgM assay was 2.5 arbitrary units per mL (AU/mL) and 4.7 AU/mL for the HAMA-IgG ELISA. Diluted serum samples showed good parallelism with the HAMA-IgM and HAMA-IgG standard dose-response curves. Within-assay coefficient of variation was 7.5% for HAMA-IgM and 6.5% for HAMA-IgG. Between-assay variation was 14.2% for HAMA-IgM and 15.3% for HAMA-IgG. The developed HAMA-IgM and HAMA-IgG ELISAs show satisfactory reliability criteria (sensitivity, parallelism and precision) and are suitable for monitoring of HAMA-IgM and HAMA-IgG responses in ovarian cancer patients. These ELISAs will be used to monitor the development of HAMAs in patients who received radioimmunotherapy with murine HMFG1.

