Related Experiment Video
Updated: Jul 10, 2026

Optocardiography and Electrophysiology Studies of Ex Vivo Langendorff-perfused Hearts
Published on: November 7, 2019
Single-site ventricular and biventricular pacing: investigation of latest depolarization strategy
Michael W Kimmel1, Nicholas D Skadsberg, Charles L Byrd
1Department of Surgery, University of Minnesota, B172 Mayo, MMC 107, 420 Delaware Street SE, Minneapolis, MN 55455, USA.
Abstract:
Aims Cardiac resynchronization therapy with biventricular pacing has proved beneficial in symptomatic heart failure patients, yet the effects in patients with structurally normal hearts remain unknown. We hypothesized that, in an acute swine model with normal anatomy and function, single-site right ventricular (RV) pacing would better preserve haemodynamic function and electrical activation compared to biventricular pacing. Methods Endocardial single-site pacing was performed in anesthetized swine (n = 7) from the RV septum and RV apex. Biventricular pacing was performed using an epicardial left ventricular (LV) lead and a RV lead. High-resolution, non-contact mapping was employed to record LV activation sequences simultaneously with haemodynamic data after 5 min of consistent capture. Results All pacing interventions significantly prolonged QRS and total endocardial activation durations (P < 0.05) compared to intrinsic activation. Biventricular pacing with the RV apex lead significantly impaired LV systolic mechanics (dP/dt(max), max LV pressure; P < 0.05), and reduced LV relaxation to the greatest extent (dP/dt(min), P = ns). Right ventricular septal pacing conserved function better than other pacing interventions (P = ns) and elicited an intrinsic electrical activation sequence. Conclusion In intact, synchronous hearts, acute biventricular pacing resulted in systolic dysfunction and abnormal LV electrical activation.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
Depolarizing Blockers: Mechanism of Action
Succinylcholine is the most commonly used depolarizing blocker. Chemically, it constitutes two molecules of acetylcholine joined together by an acetate methyl group. They act on the receptors in the same way as acetylcholine. Because succinylcholine...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Mechanism of Cardiac Arrhythmias