Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
A comparison of central venous-arterial and mixed venous-arterial carbon dioxide tension gradient in circulatory
K M Ho1, R Harding, J Chamberlain
1Department of Intensive Care, Royal Perth Hospital, Perth, Western Australia, Australia.
Abstract:
The arterial and mixed venous carbon dioxide tension gradient has been shown to increase when there is a decrease in cardiac output. Monitoring central venous gases is an attractive alternative to monitoring mixed venous gases in circulatory failure because central venous catheterisation is a less invasive procedure than pulmonary artery catheterisation. This study aims to evaluate the agreement between central venous-arterial carbon dioxide (CVA-CO2) and mixed venous-arterial carbon dioxide (SVA-CO2) tension gradients and assess whether CVA-CO2 tension gradient can be used to predict cardiac output in circulatory failure. Samples of arterial, central venous and mixed venous blood were obtained from 16 patients with circulatory failure at different inspired oxygen concentrations and cardiac indexes within 24 hours of study enrolment. CVA-CO2 and SVA-CO2 tension gradient were not interchangeable numerically (bias = 0.14 mmHg, 95% limits of agreement: -3.0 to 3.2 mmHg). CVA-CO2 (Spearman correlation coefficient r = -0.385) and SVA-CO, (r = -0.578) tension gradient were significantly correlated with the cardiac index but the cardiac index only accounted for 21% and 32% of the variability of CVA-CO, and SVA-CO2 tension gradient, respectively. The ability of CVA-CO2 tension gradient (area under the ROC curve = 0.77, 95% confidence interval [CI]: 0.49-0.99; P = 0.08) to predict a low cardiac output state (cardiac index < 2.5 l/min/m2) was lower than SVA-CO2 (area under the ROC curve = 0.95, 95% CI: 0.88-0.99; P = 0.003). The utility of CVA-CO2 and SVA-CO2 tension gradient appeared to be limited to their negative predictive value to exclude a low cardiac output state when CVA-CO, or SVA-CO, tension gradient was normal (< or =5 mmHg).
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Acute Respiratory Failure-III
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...