Intubating laryngeal mask as a ventilatory device during percutaneous dilatational tracheostomy: a descriptive study
U Linstedt1, F Möller, N Grote
1Department of Anaesthesiology, Intensive Care Medicine, and Pain Therapy, Diako Hospital, Flensburg, Academic Teaching Hospital of the University of Kiel, Germany.
Background:
We use an intubating laryngeal mask (ILM) in preference to an endotracheal tube (ETT) as the ventilatory device during percutaneous dilatational tracheostomy (PDT) to overcome potential problems such as difficult ventilation, accidental extubation, damage of the ETT or of the bronchoscope, and need for additional assistant to secure the airway. We report our experience with this method.
Methods:
In this prospective observational study, PDT was performed using the ILM in 86 patients. The insertion of the ILM, the quality of ventilation, and the view of the tracheal puncture site were rated as: 'very good', 'good', 'difficult', and 'not possible with ILM'.
Results:
The bronchoscope was not damaged during any case, and all PDTs were performed by two physicians, without the need for an additional assistant. PDTs with ILM were successful in 95% of the patients (n=82). The ratings were 'very good' or 'good' in 80% of cases with regards to ventilation, in 90% for identification of relevant structures and tracheal puncture site, and in 85% for the view inside the trachea during PDT. Tracheal re-intubation was required for inadequate ventilation with ILM in four patients.
Conclusions:
The advantages of this procedure were lack of damage to the bronchoscope, the need for two instead of three persons to perform the PDT, and the excellent view inside the trachea. We recommend the ILM as a standard device for ventilation during bronchoscope-guided PDT.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: