Related Experiment Videos

Prognostic validity of brainstem electric response audiometry in infants of a neonatal intensive care unit

A Durieux-Smith1, T W Picton, P Bernard

  • 1Children's Hospital of Eastern Ontario, Ottawa, Canada.

Insights

Brainstem electric response audiometry (BERA) accurately predicted hearing status in 89% of infants tested. Discrepancies were mainly due to temporary conductive hearing losses, highlighting BERA

Area of Science:

  • Audiology
  • Neonatal Medicine
  • Pediatric Hearing

Background:

  • Neonatal intensive care unit (NICU) infants are at high risk for hearing impairment.
  • Early detection of hearing loss is crucial for timely intervention and better outcomes.

Purpose of the Study:

  • To compare the predictive accuracy of Brainstem Electric Response Audiometry (BERA) in NICU infants with pure-tone audiometry (PTA) results at 3 years of age.
  • To identify discrepancies between BERA and PTA and analyze their causes.

Main Methods:

  • Prospective study comparing BERA in infancy with PTA at 3 years.
  • Included 333 NICU infants with complete follow-up data from an initial cohort of 600.
  • Analyzed prediction accuracy and causes of discrepancies.

Main Results:

  • BERA accurately predicted hearing status in 89% of children at 3 years.
  • Discrepancies (9%) were primarily related to transient conductive hearing losses.
  • Two cases of false-positive sensorineural hearing loss and six false-negative cases were noted.

Conclusions:

  • BERA is a reliable tool for predicting hearing status in NICU infants.
  • Transient conductive hearing loss can cause temporary discrepancies.
  • Regular follow-up is essential for accurate long-term hearing assessment in high-risk infants.