Regulated and non-regulated emissions from in-use diesel-electric switching locomotives

Aniket A Sawant1, Abhilash Nigam, J Wayne Miller

  • 1College of Engineering--Center for Environmental Research and Technology, and Department of Chemical and Environmental Engineering, Bourns College of Engineering, University of California, Riverside, California 92521, USA.

Related Concept Videos

Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
Otto and Diesel Cycle01:27

Otto and Diesel Cycle

An Otto engine is a four-stroke engine that uses a mixture of gasoline and air as the working fuel. The fuel is injected into the cylinder, and the piston is moved completely down so that the cylinder is at maximum volume. By moving the piston up, adiabatic compression takes place. The spark plug ignites the gasoline-air mixture, and the burning fuel adds heat to the system at a constant volume. The heated mixture expands adiabatically and gets further cooled by exhausting heat, and this cyclic...
Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...