Related Experiment Video
Updated: Jul 10, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Does computer-aided detection (CAD) contribute to the performance of digital mammography in a self-referred
Beniamino Brancato1, Nehmat Houssami, Damiana Francesca
1Centro per lo Studio e la Prevenzione Oncologica , Tuscany Cancer Institute, 50131, Florence, Italy.
Background:
Recent evidence suggests that computer-aided detection (CAD) may have a negative impact on the interpretation of mammography-this necessitates timely evaluation of CAD in practice. We report a retrospective study of the incremental effect of CAD on the accuracy of full-field digital mammography (DM) as applied prospectively in breast assessment.
Methods:
Subjects were all consecutive women attending a self-referral breast centre in Florence between September 2005 and January 2007 (N = 3,425). DM was reported without, then with, CAD according to a standard protocol; all mammograms recalled on the basis of either the radiologist's reading alone, or the radiologist's reading after viewing CAD, were recalled to assessment.
Results:
Overall recall rate (RR) was 13.1% and 107 cancers were diagnosed (90 invasive cancers, 8 DCIS, 9 malignant on cytology). The use of CAD allowed the additional detection of 5 cancers (three invasive cancers, one DCIS, one malignant on cytology) and caused one additional benign surgical biopsy, with a relative RR of 4.9%, and an incremental RR of 1.17%. The cancer detection rate (CDR) of DM interpreted with the use of CAD was 3.12% and did not significantly differ from the CDR of 2.9% based on DM without CAD (chi(2) = 3.2, P = 0.07).
Conclusion:
While the increase in CDR with the use of CAD only approached statistical significance, representing modest gains in absolute terms, the incremental number of cancers detected justifies the incremental recall and benign surgical biopsy attributable to CAD use. In our clinical setting, these data suggest more benefit than harm in using CAD with DM, and we will continue the use of CAD with ongoing monitoring of patient outcomes.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

