Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Novel long-term implantable blood pressure monitoring system with reduced baseline drift
Peng Cong1, Darrin J Young, Brian Hoit
1EECS Dept., Case Western Reserve Univ., Cleveland, OH, USA.
Abstract:
A novel long-term less-invasive blood pressure monitoring system with fluid-filled cuff is proposed for advanced biological research. The system employs an instrumented elastic cuff attached with a rigid isolation ring on the outside wall of the cuff. The cuff is wrapped around a blood vessel for real-time blood pressure monitoring. The elastic cuff is made of bio-compatible soft silicone material and is filled with bio-compatible insulating silicone oil with an immersed MEMS pressure sensor. This technique avoids vessel penetration and substantially minimizes vessel restriction due to the soft cuff elasticity, thus attractive for long-term monitoring. A rigid isolation ring is used to isolate the cuff from environmental variations to suppress baseline drift in the measured waveform inside the monitoring cuff. The prototype monitoring cuff is wrapped around the right carotid artery of a laboratory rat to measure real-time blood pressure waveform. The measured in vivo blood waveform is compared with a reference waveform recorded simultaneously by using a commercial catheter-tip transducer inserted into the left carotid artery, showing matched waveforms with a scaling factor about 0.03 and a baseline drift of 0.6 mm Hg. The measured baseline drift is three times smaller compared to using a cuff without a rigid isolation ring.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: