Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Cuffless and noninvasive tonometry mean arterial pressure measurement by physiological characteristics and applied
Mikyoung Park1, HeeJung Kang, Young Huh
1Bio-electronic Sensor Lab., Korea Electrotechnol. Res. Inst., Ansan, Korea.
Abstract:
We developed a cuffless and noninvasive measurement technique of blood pressure using tonometric pressure sensor. With observation that the maximum value of a pulse pressure is not obtained at mean arterial pressure (MAP), we have figured out MAP based on the physiological characteristic including the elasticity of wrist tissue, the depth of blood vessel. Through an analysis of 198 clinic data, we have induced the regression equation of the MAP. The probability of the elasticity, depth and AP(M) to explain MAP was 92.1%. The mean difference and the standard deviation between the MAP predicted from the regression equation and the MAP measured by commercial cuff type BP meter were Z-3.183 mmHg and 5.133 mmHg respectively. Comparing the results with the American national standard for electronic or automated sphygmomanometers, we can conclude that the results are quite reliable and promising. Detecting only one part of the body and using only one device are quite advantageous over other BP measurement technique. Our technique makes new way for the cuffless BP measurement.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: