A denuder-filter sampling technique for the detection of gas and particle phase carbonyl compounds
Brice Temime1, Robert M Healy, John C Wenger
1Department of Chemistry and Environmental Research Institute, University College Cork, Cork, Ireland.
Abstract:
A denuder-filter sampling technique for the simultaneous collection of gas and particle phase carbonyl compounds has been developed and tested. The denuder was coated with XAD-4 resin and the derivatizing agent O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) to enable on-tube conversion of gas-phase carbonyls to their oxime derivatives which were extracted and identified by GC-MS. The performance of the PFBHA-coated denuder was tested on a range of carbonyls, dicarbonyls, aromatic aldehydes, carbonyl-containing furans, and benzoquinones. The collection efficiency of the PFBHA-coated denuder was over 90% for sampling times of 10 min and significantly higher than when using only XAD-4 as the sorbent. The collection efficiency and rate of on-tube derivatization was highest for aldehydes and lowest for ketones, consistent with the expected reactivity of carbonyls with PFBHA. The method was used to separate the gas and particle phase carbonyl products formed during the photooxidation of toluene in order to assess its potential for application to simulation chamber experiments of VOC oxidation. The results indicate that when compared to a conventional filter sampling setup, the PFBHA-coated denuder-filter reduced the extent of gas phase adsorption onto the filter by at least a factor of 2 for each of the carbonyls formed. Further potential applications of the denuder-filter sampling method are discussed.
More Related Videos
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
10:42Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)