Related Experiment Video
Updated: Jul 10, 2026

Preparation of Functional Silica Using a Bioinspired Method
Published on: August 1, 2018
Stepwise complexometric determination of aluminium, titanium and iron concentrations in silica sand and allied
1National Physical Laboratory, Dr K S Krishnan Marg, New Delhi, India. nijhuma@hotmail.com
Background:
This study aimed at measuring the quantities of Al, Ti and Fe in silica sand and allied materials employing a complexometric method in the same analyte and a stepwise indirect titration with EDTA. The method involves the complexation of Al, Ti and Fe with excess EDTA and the selective de-complexation of TiO-EDTA and Al-EDTA complexes with tartaric acid and NaF respectively. In addition to its simplicity, rapidity and accuracy, the proposed method does not require the use of a separation technique or any sophisticated instrumentation.
Results:
Each of the test samples were analyzed five times using the proposed method. The method's accuracy was confirmed by analyzing the US National Institute of Standards and Technology's (NIST) Standard Reference Materials (SRM) 81a, 89 and IPT SRM 61 using the procedure proposed, in addition to analyzing Ti and Fe levels by spectrophotometry and that of Al by complexometry.
Conclusion:
The study shows that there is good agreement between the proposed and existing methods. The standard deviations of the measurements were calculated by analyzing five replicates of each sample, and were found to be less than 1.5% in our method.
Related Concept Videos
Complexometric Titration: Overview
Complexometric Titration: Ligands
EDTA: Indirect and Alkalimetric Titration
Complexometric EDTA Titration Curves
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Design Example: Aggregate Gradation
The grading, or particle-size distribution, of sand is determined using sieve analysis, with standard sizes ranging from 150 μm to 10 mm (ASTM No. 100 sieve to 3⁄8 in. sieve). Sand is sampled...