Related Experiment Video
Updated: Jul 10, 2026

Implantation Protocol of the Foldable Capsular Vitreous Body for Complex Vitreoretinal Surgery
Published on: April 14, 2026
Delayed accumulation of lens material behind the foldable intraocular lens
Harsha Bhattacharjee1, Kasturi Bhattacharjee, Pankaj Bhattacharjee
1Sri Sankaradeva Nethralaya, Beltola, Guwahati, Assam, India. ssnghy1@sify.com
Abstract:
Foldable acrylic intraocular lenses (IOLs) are known to reduce posterior capsule opacification by preventing migration of lens epithelial cells with its square edge design and its property of tackiness. Studies have reported a mean adhesiveness to posterior capsule more than three times higher for certain acrylic foldable IOLs than polymethyl methacrylate IOLs. The authors would like to report two cases where the force of tackiness was compensated, thereby presenting with delayed accumulation of lens material in the capsular bags behind the IOL with temporary loss of vision.
Related Concept Videos
Focusing of Light in the Eye
Glaucoma: Overview
Angle Closure Glaucoma: Treatment