Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Physiological diurnal variability and characteristics of the ocular pulse amplitude (OPA) with the dynamic contour
Sayeh Pourjavan1, Pierre-Yves Boëlle, Michéle Detry-Morel
1Department of Ophthalmology, St. Luc University Hospital, Universite Catholique De Louvain, Brussels, Belgium. sayehpourjavan@yahoo.com
Purpose:
The Pascal dynamic contour tonometer (DCT) allows measurement of intraocular pressure (IOP) independently of corneal properties. It records, simultaneously, haemodynamic IOP fluctuations and the difference between the systolic and the diastolic IOP corresponding to the ocular pulse amplitude (OPA). The OPA indirectly reflects choroidal perfusion and could be considered as an independent risk factor in glaucoma. We aimed to establish the physiological diurnal variability of the OPA and its correlations with other biophysical parameters because its characteristics remain partly unclear.
Method:
Prospective study including 52 eyes of 28 normal subjects with Goldmann applanation tonometry (GAT) IOPs < 22 mmHg. Subjects treated with systemic medications that could interfere with blood pressure or heart rate were excluded. IOP was measured at 9:00 am, 1:00 pm, and 4:00 pm by GAT and DCT. Two consecutive GAT followed by three consecutive DCT measurements were performed in each session by the same clinician (SP). Only DCT measurements with quality 1 and 2 were taken into account. Blood pressure, pulse rate, and central corneal thickness (CCT) were recorded after the last IOP measurements. Spearman correlation coefficient was used for assessment of correlations.
Results:
Mean age was 40 +/- 14 years. Mean DCT values were significantly higher than GAT readings (mean = 16.8 +/- 2.0 vs. 15.2 +/- 2.8 mmHg, P < 0.02). The mean OPA was 2.2 +/- 0.7 mmHg (range: 1-3.4 mmHg). The mean amplitude of diurnal OPA fluctuations was 0.4 mmHg. There was no significant difference in the mean OPA values at each time of the diurnal curve. The intraclass correlation (ICC) of only one OPA measurement in relation to part of total variance due to inter-measurement variation was 78%. Averaging over three independent readings of OPA improved ICC to 91%. The OPA was correlated with GAT (r = 0.31, P < 0.0001) and DCT IOP measurements (r = 0.49, P < 0.0001). It was correlated neither with blood pressure nor with age. OPA values of both eyes of the same individual were highly correlated (r = 0.89, P < 0.0001).
Conclusion:
In normal healthy eyes, the ocular pulse amplitude remains stable during normal outpatient office hours and was not correlated with blood pressure or age of patients.
Related Concept Videos
Measurement of Blood Pressure
Pulse
The pulse serves as a clinical indicator...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ophthalmic Drug Delivery Systems
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...