Determination of linezolid in pharmaceutical dosage forms by liquid chromatography and ultraviolet spectroscopy

Satish A Patel1, Paresh U Patel, Natubhai J Patel

  • 1Shree S.K. Patel College of Pharmaceutical Education and Research, Ganpat Vidyanagar, Kherava-382 711, Mehsana, Gujarat, India.

Related Concept Videos

Protein-Drug Binding: Determination Methods01:22

Protein-Drug Binding: Determination Methods

Determining protein-drug binding can be achieved through indirect and direct methods, each providing valuable insights into the interaction between proteins and drugs.
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses01:25

Determination of Multiple Dosing Parameters: Loading and Maintenance Doses

A loading dose is an essential pharmacological strategy to rapidly achieve the target plasma drug concentration necessary for an immediate therapeutic effect. This approach is especially critical for drugs characterized by slow absorption or extended half-lives, where delaying therapeutic plasma levels could compromise treatment outcomes. By administering a loading dose, clinicians ensure a prompt onset of drug action, even for agents with complex pharmacokinetic profiles.Achieving steady-state...
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte properties and...
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...