Related Experiment Video
Updated: Jul 10, 2026

E-Patient Counseling Trial (E-PACO): Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
The renal safety of bowel preparations for colonoscopy: a comparative study of oral sodium phosphate solution and
A K Singal1, A S Rosman, J B Post
1Department of Medicine, James J. Peters VA Medical Center, Bronx, NY 10468, USA.
Background:
Rare cases of nephrotoxicity have been reported with oral sodium phosphate solution (OSPS).
Aim:
To evaluate whether OSPS is associated with changes in renal function.
Methods:
A chart review performed on 311 patients who had colonoscopy at the James J. Peters VA Medical Centre prepared with either OSPS (n = 157) or polyethylene glycol (PEG) (n = 154). Patients had a baseline serum creatinine
Results:
Oral sodium phosphate solution resulted in a slight increase in serum creatinine from 1.0 +/- 0.02 to 1.1 +/- 0.02 mg/dL (P = 0.07) and PEG resulted in a small decrease in serum creatinine from 1.1 +/- 0.02 to 1.0 +/- 0.03 mg/dL (P = 0.03). The absolute change in serum creatinine was slightly higher with OSPS than with PEG (0.04 +/- 0.02 vs. -0.05 +/- 0.02 mg/dL; P = 0.005). However, the proportion of patients who had a >or=50% increase above their baseline creatinine was similar (OSPS vs. PEG, 5% vs. 3%, P = 0.77).
Conclusions:
Oral sodium phosphate solution was associated with a slight increase in serum creatinine, which was not clinically significant. Renal toxicity from OSPS appears to be minimal when used in patients with serum creatinine value <1.5 mg/dL.
Related Concept Videos
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...