High-resolution computed tomography with single-slice computed tomography and 16-channel multidetector computed
J Vikgren1, M Båth, A A Johnsson
1Departments of Radiology, and Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Göteborg, Sweden.
Background:
High-resolution computed tomography is the image procedure of choice in the evaluation of interstitial lung disease. Multidetector-row computed tomography provides the possibility of simultaneous reconstruction of thin and thick slices from the same raw data, acquired from one single series. Thus, it may be tempting to exclude the step-and-shoot series.
Purpose:
To compare high-resolution computed tomography (HRCT step-and-shoot) from single-slice CT (SSCT) and 16-channel multidetector CT (MDCT) in terms of visibility and motion artifacts, and to investigate whether thin images reconstructed from helical MDCT are equal to or better than conventional HRCT by SSCT in terms of visibility and motion artifacts.
Material And Methods:
20 patients underwent HRCT step-and-shoot by SSCT (SSCT step-and-shoot) and MDCT (MDCT step-and-shoot), and a helical MDCT acquisition (MDCT helical). Images from four anatomical levels were analyzed in random order regarding visibility and motion artifacts.
Results:
Visibility using MDCT step-and-shoot was significantly better than or equal to SSCT step-and-shoot for segmental bronchi and fissures, but not for subsegmental bronchi. For MDCT helical, visibility was equal to or better than SSCT step-and-shoot for segmental bronchi, but not for fissures and subsegmental bronchi. Concerning motion artifacts, MDCT step-and-shoot and MDCT helical were significantly better than or equal to SSCT step-and-shoot.
Conclusion:
The image quality (accounting for motion artifacts and visibility) of SSCT step-and-shoot and MDCT step-and-shoot is comparable. The visibility of anatomic structures in images from MDCT helical is inferior to HRCT step-and-shoot.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...