Related Experiment Video
Updated: Jul 10, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Hematology patterns after hemoglobin-based oxygen carrier resuscitation from severe controlled hemorrhage with
Francoise Arnaud1, Daniel Fasipe, Nora Philbin
1Trauma and Resuscitative Medicine Department, Naval Medical Research Center, Silver Spring, Maryland 20910-7500, USA. arnaudf@nmrc.navy.mil
Background:
The hemoglobin-based oxygen carrier (HBOC-201) resuscitation fluid improves outcome in hemorrhagic shock swine models with minimal coagulopathy. Herein, coagulation parameters were evaluated after resuscitation with HBOC-201 after severe bleeding and prolonged delay to definitive care.
Study Design And Methods:
After 55 percent estimated blood volume-controlled hemorrhage by catheter withdrawal, swine (n=48) were resuscitated with HBOC-201 or Hextend (HEX) infused in four doses over 4 hours or not resuscitated (NON). Animals were randomly assigned in two cohorts of 4- or 24-hour simulated delay to hospital arrival (access to blood and saline infusions up to 72 hr). In vitro hematologic monitoring was assessed with complete blood count, hemostasis (thromboelastography [TEG], in vitro bleeding time [PFA]), and coagulation (prothrombin time [PT], thrombin-antithrombin, fibrinogen) indices.
Results:
Within groups, survival was unaffected by extending delay from 4 to 24 hours. Combined survival was similar for HBOC-201 and HEX but lower for NON animals (93.5, 81.5, and 25 percent, respectively; p<0.01). Blood transfusion requirements were lower with HBOC-201 than HEX. Elevated TEG and PFA parameters in resuscitated animals reflected fluid and blood transfusion regimens. TEG reaction time and PFA were transiently higher with HBOC-201 than with HEX during the early hospital phase. PT was increased in HEX animals.
Conclusion:
In this severe model, survival was equivalent with HBOC-201 and HEX resuscitation. HBOC-201 or HEX allowed delayed hospital arrival to 24 hours without worsening coagulation parameters, but dilutional mild coagulopathy in the hospital phase persisted with HBOC-201 due to blood transfusion avoidance. Low hematocrit suggests that blood administration after HBOC-201 resuscitation could be beneficial to replete blood cellular mass.
More Related Videos
Related Concept Videos
Hemorrhagic Stroke ll: Pathophysiology
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Oxygen Transport in the Blood
Respiration and Gaseous Exchange
Respiration involves the exchange of gases, especially oxygen (O2) and carbon dioxide (CO2), between the alveoli and body cells, a process facilitated by blood circulation. As a result, the cardiovascular system, which involves the...
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: