The effectiveness of preformed tooth protectors during endotracheal intubation: an upper jaw model
Enrico Monaca1, Norbert Fock, Manfred Doehn
1Department of Anesthesiology and Intensive Care Medicine, Hospital Cologne-Merheim, University of Witten/Herdecke, Germany. MonacaE@Kliniken-Koeln.de
Background:
In anesthetic practice, tooth damage may impair patient safety and is a common reason for litigation. The use of dental shields may reduce this complication. In this study, we examined the effectiveness of dental shields for altering the force on the teeth during endotracheal intubation.
Methods:
Five preformed dental shields (Endoragard, Ormco, Nouveau Dispositif (ND), PEB, and Camo) were evaluated in three different categories: (a) horizontal force reduction, (b) axial force reduction, and (c) impact on the view of the oral cavity. Force reduction was examined by using an upper jaw model. The upper incisors of the model were covered with each of the dental shields and then loaded with a force of 150 N via a blade of a laryngoscope directed to the maxillary left central incisor (tooth 9). The force distributed to the four maxillary central and lateral incisors by the dental shield was also measured by strain gauges placed to estimate the force applied to each tooth. The reduction in oral view was determined by measuring the thickness of each dental shield with a micrometer.
Results:
Dental shield Ormco Sports-Guard achieved the highest force reduction results, followed by Camo and Endoragard. ND and PEB showed poor, but statistically significant, force reduction with either the worst axial (ND) or horizontal (PEB) results. In contrast, Ormco was the most voluminous model, followed by ND and Camo. PEB and Endoragard were the thinnest models.
Conclusions:
Preformed dental shields are useful to reduce the force applied to the teeth and potentially reduce the probability of tooth damage during laryngoscopy. However, the shield with the most force reduction capability is rather large and also expensive, making general use impossible. Further prospective studies are needed to evaluate efficacy and safety of tooth protectors.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...