Simultaneous Affinity Enrichment of Two Post-Translational Modifications for Quantification and Site Localization
Published on: February 27, 2020
Automated interface for hyphenation of planar chromatography with mass spectrometry
Heinrich Luftmann1, Mario Aranda, Gertrud E Morlock
1Institute of Organic Chemistry, University of Münster, Münster, Germany.
Abstract:
A fully automated interface to couple high-performance thin-layer chromatography (HPTLC) with mass spectrometry (MS) is described. This universal hands-free interface connects intact normal-phase plates to any liquid chromatography/mass spectrometry (LC/MS) system without any adjustments or modifications to the mass spectrometer. The interface extracts the complete substance band with its depth profile and thus allows detections in the pg/band range. The high performance of the automated interface was evaluated through caffeine quantification in real samples, viz., energy drinks and pharmaceutical tablets, without internal standard. Following chromatographic separation on silica gel 60 F(254) HPTLC plates, caffeine bands were eluted from the plate by means of the automated interface to the electrospray ionization (ESI) source of a triple-quadrupole mass spectrometer. Since in full scan mode only the protonated molecule [M+H](+) was observed, caffeine quantification was performed using the selected-ion monitoring (SIM) mode at m/z 195. The validation showed highly reliable results for the linear range (R(2) = 0.9973), repeatability (RSD = 5.6%, n = 6) and intermediate precision (RSD = 1.5%, n = 3). Regarding accuracy the results obtained by HPTLC/MS were not statistically different (F-test, t-test) from those obtained by validated HPTLC/UV methods. Hence, this interface proved to be one of the most reliable and universal interfaces for HPTLC/MS.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Tandem Mass Spectrometry