Ophthalmic artery Doppler as a measure of severe pre-eclampsia
A L D Diniz1, A F Moron, M C dos Santos
1Department of Obstetrics and Gynecology, Federal University of Uberlândia, Uberlândia, Brazil. angelyca@uai.com.br
Objective:
To identify differences in orbital flow behavior in mild and severe pre-eclamptic women compared with healthy pregnant women, demonstrated by ophthalmic artery Doppler indexes.
Methods:
Ophthalmic artery Doppler indexes of 20 mild and 20 severe pre-eclamptic women were compared with 51 healthy pregnant women. Right and left eye Doppler index means were evaluated and the resistance index (RI), pulsatility index (PI), peak systolic velocity (PSV), end diastolic velocity (EDV), and peak ratio (PR) were calculated.
Results:
Statistically significant differences were observed between PR, PSV, and EDV (P=0.0009, P=0.0020, P=0.0001) ophthalmic artery Doppler in a comparison of women with mild and severe pre-eclampsia. Statistically significant differences were seen between all Doppler indexes of the study group and healthy pregnant women. Ophthalmic PR, PSV, and EDV were significantly higher in severe pre-eclamptic cases but other index parameters did not show any difference. An elevation of diastolic and systolic flow occurred when pre-eclampsia became severe.
Conclusion:
Orbital vascular impedance reduction with orbital hyperperfusion was present in severe pre-eclamptic women compared with mild pre-eclamptic and healthy pregnant women. Ophthalmic Doppler is a novel parameter that may be useful in the diagnosis of severe pre-eclampsia.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...