Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Modifiable factors related to 7-year renal outcomes in subjects with type 2 diabetes and chronic kidney disease stage 3.

Journal of postgraduate medicine·2020
Same author

Re-focusing on Agnathia-Otocephaly complex.

Clinical oral investigations·2020
Same author

YAP/TAZ Regulate Elevation and Bone Formation of the Mouse Secondary Palate.

Journal of dental research·2020
Same author

First trimester placental vascular indices and volume by three-dimensional ultrasound in pre-gravid overweight women.

Placenta·2019
Same author

[Study on the mechanism of serotype conversion of historical isolates of <i>Shigella flexneri</i>].

Zhonghua yu fang yi xue za zhi [Chinese journal of preventive medicine]·2018
Same author

Axillary web syndrome following epidermal inclusion cyst: a case report and literature review.

Clinical and experimental dermatology·2018

Related Experiment Video

Updated: Jul 10, 2026

Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture
10:00

Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture

Published on: July 20, 2022

A compact computational model for cell construct development in perfusion culture.

C A Chung1, C P Chen, T H Lin

  • 1Department of Mechanical Engineering, National Central University, Jhongli 32001, Taiwan. cachung@ncu.edu.tw

Biotechnology and Bioengineering
|November 1, 2007
PubMed
Summary

A new compact model accurately simulates cell growth in tissue engineering scaffolds using direct perfusion. This simplified approach enhances nutrient transport and waste removal for developing larger tissue implants.

More Related Videos

A Versatile Automated Platform for Micro-scale Cell Stimulation Experiments
12:21

A Versatile Automated Platform for Micro-scale Cell Stimulation Experiments

Published on: August 6, 2013

Ex Vivo Perfusion Culture of Large Blood Vessels in a 3D Printed Bioreactor
06:44

Ex Vivo Perfusion Culture of Large Blood Vessels in a 3D Printed Bioreactor

Published on: July 28, 2023

Related Experiment Videos

Last Updated: Jul 10, 2026

Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture
10:00

Multi-Stream Perfusion Bioreactor Integrated with Outlet Fractionation for Dynamic Cell Culture

Published on: July 20, 2022

A Versatile Automated Platform for Micro-scale Cell Stimulation Experiments
12:21

A Versatile Automated Platform for Micro-scale Cell Stimulation Experiments

Published on: August 6, 2013

Ex Vivo Perfusion Culture of Large Blood Vessels in a 3D Printed Bioreactor
06:44

Ex Vivo Perfusion Culture of Large Blood Vessels in a 3D Printed Bioreactor

Published on: July 28, 2023

Area of Science:

  • Biomedical Engineering
  • Tissue Engineering
  • Computational Biology

Background:

  • Nonuniform cell and extracellular matrix spread hinders the development of large tissue implants.
  • Nutrient transport limitations are a key challenge in tissue engineering.
  • Hydrodynamic culture systems offer a potential solution to improve nutrient distribution.

Purpose of the Study:

  • To develop a simplified, compact mathematical model for simulating cell growth in porous tissue engineering scaffolds under direct perfusion.
  • To assess the accuracy of the compact model compared to existing, more complex models.
  • To provide a computationally efficient tool for tissue engineering construct development.

Main Methods:

  • Development of a single-layer mathematical model representing the porous scaffold.
  • Simulation of cell growth, nutrient transport, and metabolic waste distribution within the scaffold.
  • Comparison of simulation results with a previously established three-layer model.

Main Results:

  • The compact single-layer model accurately predicts cell spread and nutrient/waste distribution.
  • The model achieves comparable accuracy to the more complex three-layer model.
  • The simplified model is sufficient unless detailed hydrodynamic factors like pressure and viscous stress are critical.

Conclusions:

  • The proposed compact model offers a computationally efficient and accurate method for simulating tissue engineering constructs.
  • This model can aid in the development of larger, more viable tissue implants.
  • The simplified approach is suitable for most tissue engineering applications, with complex models reserved for specific hydrodynamic analyses.