Related Experiment Video
Updated: Jul 10, 2026

Using Simulation Models to Train Clinicians in the Use of Point-of-Care Ultrasound
Published on: August 9, 2024
Job analysis and student assessment tool: perfusion education clinical preceptor
1Circulation Technology Program and Division, School of Allied Medical Professions, College of Medicine, The Ohio State University, Columbus, Ohio 43210, USA. riley.267@osu.edu
Abstract:
The perfusion education system centers on the cardiac surgery operating room and the perfusionist teacher who serves as a preceptor for the perfusion student. One method to improve the quality of perfusion education is to create a valid method for perfusion students to give feedback to clinical teachers. The preceptor job analysis consisted of a literature review and interviews with preceptors to list their critical tasks, critical incidents, and cognitive and behavioral competencies. Behaviorally anchored rating traits associated with the preceptors' tasks were identified. Students voted to validate the instrument items. The perfusion instructor rating instrument with a 0-4, "very weak" to "very strong" Likert rating scale was used. The five preceptor traits for student evaluation of clinical instruction (SECI) are as follows: The clinical instructor (1) encourages self-learning, (2) encourages clinical reasoning, (3) meets student's learning needs, (4) gives continuous feedback, and (5) represents a good role model. Scores from 430 student-preceptor relationships for 28 students rotating at 24 affiliate institutions with 134 clinical instructors were evaluated. The mean overall good preceptor average (GPA) was 3.45 +/- 0.76 and was skewed to the left, ranging from 0.0 to 4.0 (median = 3.8). Only 21 of the SECI relationships earned a GPA < 2.0. Analyzing the role of the clinical instructor and performing SECI are methods to provide valid information to improve the quality of a perfusion education program.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse Assessment Sites
