Related Experiment Video
Updated: Jul 10, 2026

06:42
Generation and Coherent Control of Pulsed Quantum Frequency Combs
Published on: June 8, 2018
Phase matching in femtosecond BOXCARS
D Romanov1, A Filin, R Compton
1Center for Advanced Photonics Research, College of Science and Technology, Department of Physics, Temple University, Philadelphia, PA 19122, USA.
Optics Letters
|November 3, 2007
Abstract:
We analytically describe the effect of phase-matching conditions on femtosecond BOXCARS line shape and demonstrate quantitative agreement with experimental spectra for the oxygen vibrational transition, DG01=1556.4 cm(-1).
Related Concept Videos
Time and frequency -Domain Interpretation of Phase-lead Control
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Double Resonance Techniques: Overview
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.