Related Experiment Video
Updated: Jul 10, 2026

Synergizing Antegrade Endoscopic with Bridging Vein Harvesting for Improvement of Great Saphenous Vein Graft Quality from the Lower Leg
Published on: November 19, 2019
Strategies to reduce intraluminal clot formation in endoscopically harvested saphenous veins
Emile N Brown1, Zachary N Kon, Richard Tran
1Department of Surgery, Division of Cardiac Surgery, University of Maryland School of Medicine, Baltimore, Md 21201, USA.
Objective:
Residual clot strands within the excised saphenous vein are an increasingly recognized sequela of endoscopic vein harvest. We hypothesized that endoscopic visualization facilitated by sealed carbon dioxide insufflation causes stagnation of blood within the saphenous vein. In the absence of prior heparin administration, this stasis provokes clot formation.
Methods:
Forty consecutive patients having coronary artery bypass grafting underwent endoscopic vein harvest using sealed (Guidant VasoView, n = 30; Guidant Corp, Minneapolis, Minn) or open (Datascope ClearGlide, n = 10; Datascope Corp, Montvale, NJ) carbon dioxide insufflation followed by ex vivo assessment of intraluminal saphenous vein clot via optical coherence tomography. In the sealed carbon dioxide insufflation groups, clot formation was compared with (preheparinized, n = 20) and without (control, n = 10) heparin administration before endoscopic vein harvest, either at a fixed dose or titrated to an activated clotting time greater than 300 seconds. Risk factors for clot formation were assessed.
Results:
Residual saphenous vein clot was a universal finding in control veins (sealed carbon dioxide insufflation endoscopic vein harvest without preheparinization). At either dose used, heparin given before endoscopic vein harvest significantly decreased saphenous vein clot burden. A similar reduction in clot was observed when using open carbon dioxide insufflation endoscopic vein harvest without preheparinization. Intraoperative blood loss and blood product requirements were similar in all groups. Patient age and preoperative maximum amplitude of the thrombelastography tracing showed a linear correlation with saphenous vein clot volume.
Conclusion:
By enabling the quantification of this issue as never before possible, optical coherence tomography screening revealed that intraluminal saphenous vein clot is frequently found after endoscopic vein harvest. Systemic heparinization before harvest or an open carbon dioxide endoscopic vein harvest system are benign changes in practice that can significantly lessen this complication.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis IV: Nursing Management
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol abuse, or...
Veins of Lower Limbs
Formed by the union of the medial and lateral plantar veins, the posterior tibial vein, rising through the calf muscle, assimilates the fibular vein. The anterior tibial vein, a superior extension of the foot's dorsalis pedis vein, merges with the posterior tibial vein at the knee,...