Predictors of success in nurse-performed ultrasound-guided cannulation

Brian Chinnock1, Stephen Thornton, Gregory W Hendey

  • 1Department of Emergency Medicine, Community Regional Medical Center, UCSF-Fresno Medical Education Program, Fresno, California 93701, USA.

The objective of this study was to characterize factors affecting the success rate of nurse-performed ultrasound (US)-guided peripheral vein cannulation in difficult access patients. We prospectively enrolled patients who had two previous unsuccessful i.v. attempts. Nurses were trained in US-guided cannulation using a 7.5-MHz linear probe. The following characteristics were recorded: 1) reason for difficult access, 2) which upper arm veins could be sonographically visualized, 3) cannulation success, and 4) one- or two-person technique used. One hundred patients were enrolled. The cannulation success rate was 63%. Cannulation of the basilic vein was successful in 39 of 55 attempts (71%), whereas the success rate for the brachial vein was only 19 of 46 attempts (41%). The reason for difficult access and the one- or two-person technique did not affect success rate. The basilic vein was the best choice for cannulation, and the one-person technique was as successful as the two-person technique.

Related Concept Videos

Ultrasound I: Abdominal Ultrasonography01:20

Ultrasound I: Abdominal Ultrasonography

Introduction:
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.
Cardiac Catheterization IV: Nursing Management01:26

Cardiac Catheterization IV: Nursing Management

Nursing responsibilities before cardiac catheterization include:Assess for allergies and establish baseline health status.Before cardiac catheterization, assess the patient for allergies to contrast dye. Perform a comprehensive baseline assessment, including vital signs, heart and breath sounds, and a neurovascular assessment of the extremities, noting distal pulses, skin color, and temperature. Instruct the patient to fast for 8-12 hours before the procedure. Evaluate baseline laboratory...