Spatial Separation of Molecular Conformers and Clusters
Published on: January 9, 2014
Increasing analytical space in gas chromatography-differential mobility spectrometry with dispersion field amplitude
Abstract:
Enhancing the analytical space of differential mobility spectrometry with dispersion field amplitude programming was proposed. Six volatile organic compound candidate breath markers, 1,3-butanediol, butanone, ethylbenzene, heptan-2-one, nonanal, and o-xylene were used to characterise the effect of programming the amplitude of the dispersion field on the sensitivity, and resolution of the responses observed. Sensitivity followed two patterns of behaviour. Sensitivity to heptan-2-one and 1,3-butanediol increased to a maximum at approximately 20 kV cm(-1), attributed to dissociative ionisation effects. The remaining four compounds' responses were dominated by wall-loss phenomena resulting in a constant reduction in sensitivity as dispersion field amplitude was increased. The effect of the dispersion field on analytical space was pronounced. At a field strength of 18 kV cm(-1) protonated monomers and proton-bound dimers could be observed within the chromatographic responses for the carbonyl compounds. Dissociative ionisation products were also discerned for 1,3-butanediol and butanone. The ion chemistry of the two hydrocarbons was not affected by the dispersion field amplitude. Resolution of the product ions and their separation from the reactant ion peaks increased significantly with increasing dispersion field amplitude. With a range of behaviours observed. Peak resolutions increased from the range 0 to 1.2 to 1.2 to 7, while resolving power increased from 0 (at low dispersion field amplitudes) to the range 0.2-6 at 20-24 kV cm(-1). The effect of programming the dispersion field amplitude on a "real-life" application was demonstrated with replicate breath samples obtained from a subject with chronic obstructive pulmonary disease.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Analyte Adsorption and Distribution
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...