Treatment of arsenic contaminated water in a batch reactor by using Ralstonia eutropha MTCC 2487 and granular activated carbon
Related Experiment Video
Updated: Jul 10, 2026

Removal of Arsenic Using a Cationic Polymer Gel Impregnated with Iron Hydroxide
Published on: June 28, 2019
P Mondal1, C B Majumder, B Mohanty
1Department of Chemical Engineering, Indian Institute of Technology Roorkee, Uttranchal, India.
Abstract:
This paper presents the observations on the bio-removal of arsenic from contaminated water by using Ralstonia eutropha MTCC 2487 and activated carbon in a batch reactor. The effects of agitation time, pH, type of granular activated carbon (GAC) and initial arsenic concentration (As(o)) on the % removal of arsenic have been discussed. Under the experimental conditions, optimum removal was obtained at the pH of 6-7 with agitation time of 100 h. The % removal of As(T) increased initially with the increase in As(o) and after attaining the maximum removal (~86%) at the As(o) value of around 15 ppm, it started to decrease. Simultaneous adsorption bioaccumulation (SABA) was observed, when fresh GAC was used as supporting media for bacterial immobilization. In case of SABA, the % removal of As(III) was almost similar (only ~1% more) to the additive values of individual removal of As(III) obtained by only adsorption and only bio-adsorption. However, for As(V) the % removal was less (~8%) than the additive value of the individual % removals obtained by only adsorption and bio-adsorption. Percentage removal of Fe, Mn, Cu and Zn were 65.17%, 72.76%, 98.6% and 99.31%, respectively. Maximum regeneration (~99.4%) of the used bio-adsorbent was achieved by the treatment with 5NH(2)SO(4) followed by 1N NaOH and 30% H(2)O(2) in HNO(3). The fitness of the isotherms to predict the specific uptake for bio-adsorption/accumulation process has been found to decrease in the following order: Temkin isotherm>Langmuir isotherm>Freundlich isotherm. For the adsorption process with fresh GAC the corresponding order is Freundlich isotherm>Langmuir isotherm>Temkin isotherm for As(V) and As(T). However, for As(III) it was Langmuir>Temkin>Freundlich.
More Related Videos
15:19Development of Sulfidogenic Sludge from Marine Sediments and Trichloroethylene Reduction in an Upflow Anaerobic Sludge Blanket Reactor
Published on: October 15, 2015
09:23Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
Related Concept Videos
Microbial Wastewater Treatment
Microbial Bioremediation of Uranium
Biological Treatment of Effluent and Waste Water
Bioremediation
Pharmaceutical Poisoning: Treatment Strategies
Prevention of Further Absorption of Poison