Related Experiment Video
Updated: Jul 10, 2026

Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Estimation of the total peripheral resistance baroreflex impulse response from spontaneous hemodynamic variability
Xiaoxiao Chen1, Jong-Kyung Kim, Javier A Sala-Mercado
1Department of Electrical and Computer Engineering, Michigan State University, 2120 Engineering Bldg., East Lansing, MI 48824, USA.
Abstract:
We previously developed a mathematical analysis technique for estimating the static gain values of the arterial total peripheral resistance (TPR) baroreflex (G(A)) and the cardiopulmonary TPR baroreflex (G(C)) from small, spontaneous beat-to-beat fluctuations in arterial blood pressure, cardiac output, and stroke volume. Here, we extended the mathematical analysis so as to also estimate the entire arterial TPR baroreflex impulse response [h(A)(t)] as well as the lumped arterial compliance (AC). The extended technique may therefore provide a linear dynamic characterization of TPR baroreflex systems during normal physiological conditions from potentially noninvasive measurements. We theoretically evaluated the technique with respect to realistic spontaneous hemodynamic variability generated by a cardiovascular simulator with known system properties. Our results showed that the technique reliably estimated h(A)(t) [error = 30.2 +/- 2.6% for the square root of energy (E(A)), 19.7 +/- 1.6% for absolute peak amplitude (P(A)), 37.3 +/- 2.5% for G(A), and 33.1 +/- 4.9% for the overall time constant] and AC (error = 17.6 +/- 4.2%) under various simulator parameter values and reliably tracked changes in G(C). We also experimentally evaluated the technique with respect to spontaneous hemodynamic variability measured from seven conscious dogs before and after chronic arterial baroreceptor denervation. Our results showed that the technique correctly predicted the abolishment of h(A)(t) [E(A) = 1.0 +/- 0.2 to 0.3 +/- 0.1, P(A) = 0.3 +/- 0.1 to 0.1 +/- 0.0 s(-1), and G(A) = -2.1 +/- 0.6 to 0.3 +/- 0.2 (P < 0.05)] and the enhancement of G(C) [-0.7 +/- 0.44 to -1.8 +/- 0.2 (P < 0.05)] following the chronic intervention. Moreover, the technique yielded estimates whose values were consistent with those reported with more invasive and/or experimentally difficult methods.
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Measurement of Blood Pressure
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Assessment of blood pressure in brachial artery(two-step method)
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:

