Related Experiment Video
Updated: Jul 10, 2026

A Preclinical Model of Exertional Heat Stroke in Mice
Published on: July 1, 2021
15-Second conducted electrical weapon exposure does not cause core temperature elevation in non-environmentally
Donald M Dawes1, Jeffrey D Ho, Mark A Johnson
1Emergency Department, Lompoc District Hospital, Lompoc, CA, USA.
Introduction:
Conducted electrical weapons (CEW) are being incorporated into the use of force continuums of law enforcement agencies in increasing numbers. The use of these weapons has been controversial, especially as related to the sudden in-custody death (ICD) phenomenon. Hyperthermia has been reported in many ICDs attributed to excited delirium, illicit drug toxicity, or other causes. There is speculation that the electrical discharge from the CEWs may contribute to the hyperthermia, presumably from muscle tetany-induced thermogenesis. The objective of this study was to investigate the effect of a prolonged discharge of a CEW on core body temperature in human subjects.
Methods:
This was a prospective, observational study of non-environmentally stressed resting adult human volunteers. Volunteers were exposed to a 15-s continuous discharge from a TASER X26 CEW. A control group conducted usual activities of daily living (ADLs). Core body temperature was measured every 15s by a swallowed telemetric temperature measuring device. Descriptive statistics were applied.
Results:
31 subjects were enrolled. 17 subjects received the TASER X26 CEW exposure, and 10 subjects carried out usual ADLs as controls. The discharge from the TASER X26 CEW did not cause an elevation in core body temperature. The range in temperatures among all subjects was 33.1-38.3 degrees C, mean 36.7+0.6. The mean temperature 1 min after exposure was 37.4+0.4. There was no change in temperature from 1 min before the exposure to 1 min, 10 min, or 20 min after the exposure in the majority of patients. One patient had a 0.2 degree increase at 20 min, three patients had a 0.1 degree decrease in temperature at 10 min or 20 min. The mean temperature for subjects in the control group was 37.1, 95% CI=36.9-37.3, and the mean for subjects in the exposed group was 36.7, 95% CI=36.4-37.1.
Conclusion:
A 15-s discharge from a TASER X26 CEW does not increase the core body temperature of resting, non-environmentally stressed adult subjects. These results challenge the speculation that this weapon technology may be contributing to the hyperthermia in subjects who die from excited delirium, drug toxicity, or other causes while in custody.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Responses to Heat and Cold Stress
