Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Estimation of the band broadening parameters in single detection size-exclusion chromatography: a comparative study
Irene Schnöll-Bitai1, Jorge Vega, Christoph Mader
1Inst. f. Phys. Chemie, A-1090 Vienna, Austria. irene.schnoell-bitai@univie.ac.at
Abstract:
Alternative approaches for the determination of band broadening in size-exclusion chromatography based on the use of exponentially modified Gaussian (EMG) functions were used to experimentally investigate the performance of two different column sets. In both cases, the columns were combined in order to cover the complete fractionation range (from 10(3) to 5x10(6) g mol(-1)), which is of interest in many applications. When analyzing experimental chromatograms the question of proper data treatment (especially the necessary smoothing routines) became obvious and is discussed accordingly. First results indicate that the exponential decay time of the EMG decreases and the standard deviation of its Gaussian component slightly increases (or remains almost constant) with increasing retention volumes. As a consequence, the total variance and the asymmetry of the EMG both decrease with the retention volume. A favorable agreement with independent experimental results (obtained by other researchers on the basis of analyzing ultra narrow standards) was found. Additionally, the skew was also investigated as a function of the retention volume and the trend was found to be in concordance with the predictions of theoretical models. The comparison with theoretical models is also discussed.
Related Concept Videos
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Principles Of Column Chromatography