Related Experiment Video
Updated: Jul 10, 2026

Use of Galleria mellonella as a Model Organism to Study Legionella pneumophila Infection
Published on: November 22, 2013
A Legionnaires' disease outbreak: a water blaster and roof-collected rainwater systems
Greg Simmons1, Sheryl Jury, Craig Thornley
1Auckland Regional Public Health Service, Auckland 1035, New Zealand. gregs@adhb.govt.nz
Abstract:
In February 2006, an outbreak of Legionnaires' disease (LD) was identified in Beachlands, a small, isolated east Auckland suburb. It was investigated through case finding, a case-control study, sampling potential sources of infection and by molecular typing (using sequence-based typing (SBT) of all Legionella pneumophila serogroup 1 (Lp1) isolates). Lp1 was isolated from the respiratory tract of one case, the roof-collected rainwater systems of five households (three associated with cases) and from a water blaster at a nearby marina. All isolates were indistinguishable, exhibiting the same SBT allele pattern. Three LD cases lived within 500m of the water blaster (the fourth case within 1250m) and downwind in prevailing conditions. Another domestic roof-collected rainwater supply contaminated by Lp1 (identical SBT pattern) was incidentally identified in another suburb 4km east of Beachlands. This is the first outbreak of LD linked to roof-collected rainwater supplies and the first isolation of Legionella from these systems in New Zealand. Aerosols containing Legionella discharged to air by the marina water blaster may have infected some cases directly or may have seeded roof-collected rainwater systems. Some cases may have been exposed by contaminated bathroom showers. Roof-collected rainwater systems need appropriate design, careful cleaning and the maintenance of hot water temperatures at a minimum of 60 degrees C to reduce the chances of Legionella multiplying. Further research into the ecology of Legionella in roof-collected rain water systems is indicated.
More Related Videos
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
08:01Glass Wool Filters for Concentrating Waterborne Viruses and Agricultural Zoonotic Pathogens
Published on: March 3, 2012
Related Concept Videos
Waterproofing and Anti-Bacterial Admixtures in Concrete
Waterproofing admixtures render concrete hydrophobic,...
Cholera
Investigation of Disease Outbreaks
Reservoir of Infection
Efflorescence in Masonry
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
Masonry in Cold and Hot Weather Conditions