Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Calculating arterial pressure-based cardiac output using a novel measurement and analysis method
Benjamin Pratt1, Luchy Roteliuk, Feras Hatib
1Edwards Lifesciences LLP, Irvine, CA 92614, USA. benjamin_pratt@edwards.com
Abstract:
Work on applying physical and physiological principles for determining cardiac output by analysis of pressure measurements has been pursued for decades. Reference measurements for this kind of cardiac output analysis rely on the pulmonary artery catheter (PAC), considered the clinical gold standard for cardiac output monitoring. Recent advances in signal processing, as well as applied information on the relationships that enable arterial pulse pressure to be used to determine stroke volume, have led to the development of a novel system that can continuously measure cardiac output from an arterial pressure waveform that does not require an external calibration reference method. There are significant challenges in applying statistical- and signal-processing practices to the analysis of complex physiological waveforms. This paper reviews the historical basis for measuring flow from the analysis of pressure in a vessel, establishes the physiological and mathematical basis for this new system and describes its performance under various physiological conditions.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessment of blood pressure in brachial artery(two-step method)