Calculating arterial pressure-based cardiac output using a novel measurement and analysis method
Benjamin Pratt1, Luchy Roteliuk, Feras Hatib
1Edwards Lifesciences LLP, Irvine, CA 92614, USA. benjamin_pratt@edwards.com
This study introduces a novel system for continuous cardiac output monitoring using arterial pressure waveforms. It eliminates the need for external calibration, offering a promising alternative to the pulmonary artery catheter (PAC).
Area of Science:
- Cardiovascular Physiology
- Biomedical Engineering
- Medical Signal Processing
Background:
- Cardiac output monitoring is crucial in clinical settings.
- Pulmonary artery catheters (PAC) are the current gold standard but are invasive.
- Existing methods for non-invasive cardiac output assessment face challenges.
Purpose of the Study:
- To review the historical basis of flow measurement from pressure analysis.
- To establish the physiological and mathematical foundation of a novel cardiac output monitoring system.
- To describe the performance of this new system under various physiological conditions.
Main Methods:
- Utilizing advances in signal processing and physiological relationships.
- Developing a system to derive cardiac output from arterial pressure waveforms.
- Analyzing complex physiological waveforms using statistical and signal-processing techniques.
Main Results:
- A novel system for continuous cardiac output measurement from arterial pressure has been developed.
- The system operates without requiring an external calibration reference method.
- Performance evaluation under various physiological conditions is described.
Conclusions:
- The novel system offers a non-invasive and potentially more accessible method for cardiac output monitoring.
- This approach leverages advanced signal processing for analyzing physiological data.
- Further validation and clinical implementation are warranted.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessment of blood pressure in brachial artery(two-step method)