Accurate automated logPo/w measurement by gradient-flow liquid-liquid partition chromatography. Part 1. Neutral
Sandrine Demare1, Bryan Slater, Gaëlle Lacombe
1Oroxcell SAS, 102 Route de Noisy, 93230 Romainville, France. sandrine.demare@oroxcell.com
Abstract:
There is a continuing need for a method which can measure logPoctanol/water accurately and precisely. Liquid-liquid partition chromatography is ideally suited for this as the retention time is a direct function of the partition or distribution coefficient. However, the range of measurements using isocratic-flow conditions is limited by the log-linear relation between run time and logPo/w. The use of gradient-flow programming and short columns gives a more versatile procedure, so that appropriate data points can be collected at both the low and high ends of the chromatographic run, corresponding to logPo/w values between 1 and 4. At the same time the precision, accuracy and versatility of the method are kept. This study is a validation of the procedure and measures the logPo/w on 23 representative pharmaceuticals, comprising a mixed set of neutral compounds. The linear plot fitting micropartition logPo/w and those found in literature shows a slope close to unity and a residuum close to zero. This indicates that gradient-flow micropartition chromatography is ruled by partitioning between octanol and the aqueous phase.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
07:11Automated HPLC Separation Using LC-Mate: An Integrated Repetitive Autosampler and Fraction Collector for Microscale Purification
Published on: February 27, 2026
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Chromatographic Methods: Terminology