Related Experiment Videos
Thrombin-soaked coils: estimation of thrombin dose
1Department of Radiology, Indiana University Hospital, Indianapolis 46203.
Journal of Vascular and Interventional Radiology : JVIR
|February 1, 1991
Summary
Thrombin-soaked coils absorb more thrombin when soaked vertically in higher concentrations for at least one minute. This finding is crucial for optimizing embolic agent dosage in medical procedures.
Area of Science:
- Interventional Radiology
- Biomaterials Science
- Biochemistry
Background:
- Thrombin-soaked coils are utilized as embolic agents for various medical conditions.
- High doses of intravascular thrombin may pose risks.
- Estimating thrombin dosage with transcatheter coils is essential for safe and effective treatment.
Purpose of the Study:
- To quantify the thrombin absorption by steel coils used in transcatheter embolization.
- To determine the impact of thrombin concentration and soaking orientation on absorption.
- To establish optimal soaking parameters for thrombin-soaked coils.
Main Methods:
- An in vitro experiment was conducted to measure thrombin absorption.
- Steel coils (8 mm x 5 cm, 0.038-inch) were soaked in varying thrombin concentrations (10,000 U/10 mL and 20,000 U/10 mL).
- Thrombin absorption was assessed based on coil orientation (vertical vs. horizontal) and soaking time.
Main Results:
- Coils soaked in higher thrombin concentrations (20,000 U/10 mL) absorbed significantly more thrombin (average 71.6 U) compared to lower concentrations (10,000 U/10 mL, average 38.4 U).
- Maximum single-coil absorption reached 45.6 U and 88.2 U for the respective concentrations.
- Thrombin absorption plateaued after 1 minute of soaking.
- Vertical orientation maximized thrombin absorption, while horizontal orientation resulted in minimal absorption.
Conclusions:
- The dose of thrombin absorbed by steel coils is dependent on the soaking solution concentration and coil orientation.
- Vertical orientation and sufficient soaking time (≥1 minute) are critical for maximizing thrombin absorption.
- These findings provide valuable data for standardizing the preparation of thrombin-soaked coils as embolic agents.