Calorespirometry: A Powerful, Noninvasive Approach to Investigate Cellular Energy Metabolism
Published on: May 31, 2018
Indirect calorimetry: a tool to adjust energy expenditure in very low birth weight infants
Fernanda V M Soares1, Maria E L Moreira, Andrea D Abranches
1Fundação Oswaldo Cruz (Fiocruz), Rio de Janeiro, RJ, Brazil.
Insights
Very low birth weight infants exhibit a high resting metabolic rate, a key factor potentially contributing to malnutrition during hospitalization. This finding highlights the importance of monitoring energy expenditure in these vulnerable infants.
Area of Science:
- Neonatalogy
- Pediatric Nutrition
- Metabolic Research
Background:
- Very low birth weight (VLBW) infants are at high risk for malnutrition.
- Accurate assessment of energy expenditure is crucial for optimizing nutritional support in VLBW infants.
Purpose of the Study:
- To quantify the resting metabolic rate (RMR) in clinically stable VLBW infants.
- To investigate the relationship between RMR and the incidence of malnutrition in VLBW infants.
Main Methods:
- A cross-sectional study involving 29 stable VLBW infants receiving >100 kcal/kg/day enteral nutrition.
- Resting energy expenditure (REE) was measured using open-circuit indirect calorimetry.
- Malnutrition was defined by a weight-for-age z-score ≤ -2 SD.
Main Results:
- The mean weight of infants was 1,564±393 g with a corrected gestational age of 35±3 weeks.
- Malnutrition was prevalent, diagnosed in 62.1% of the preterm infants.
- The mean resting metabolic rate was determined to be 57.01±7.76 kcal/kg/day.
Conclusions:
- The observed high resting metabolic rate in VLBW infants is a significant component of their total energy expenditure.
- This elevated RMR may play a critical role in the development of malnutrition during neonatal intensive care unit hospitalization.
- Further research is warranted to explore strategies for managing high energy demands in VLBW infants to prevent malnutrition.
Objective:
To determine the resting metabolic rate in very low birth weight infants through indirect calorimetry.
Methods:
Cross-sectional study including 29 clinically stable very low birth weight infants receiving an enteral diet > 100 kcal/kg/day. Malnutrition was defined as weight-for-age z score < or = - 2 SD. Resting energy expenditure was measured using open circuit indirect calorimetry.
Results:
At the time of the examination, mean weight was 1,564+/-393 g and corrected gestational age was 35+/-3 weeks. Malnutrition was diagnosed in 62.1% of the preterm infants. The mean resting metabolic rate was 57.01+/-7.76 kcal/kg/day.
Conclusion:
Since resting energy expenditure is the main caloric component of total energy expenditure, the high resting metabolic rate observed may have a strong impact on the development of malnutrition during hospitalization.
More Related Videos
Related Concept Videos
Constant Pressure Calorimetry
Constant Volume Calorimetry
Calorimetry
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Decreased Body Temperature