Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Modeling and Similitude01:12

Modeling and Similitude

Scaled modeling is a fundamental technique in engineering, enabling the study of large and complex systems by creating smaller, manageable replicas that recreate critical characteristics of the original. In hydrology and civil infrastructure, for example, scaled models of dams help analyze water flow, turbulence, and pressure. This method allows for accurate predictions of real-world behavior within a controlled environment, significantly reducing the cost and time involved in full-scale...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...
Mechanistic Models: Compartment Models in Individual and Population Analysis01:23

Mechanistic Models: Compartment Models in Individual and Population Analysis

Mechanistic models are utilized in individual analysis using single-source data, but imperfections arise due to data collection errors, preventing perfect prediction of observed data. The mathematical equation involves known values (Xi), observed concentrations (Ci), measurement errors (εi), model parameters (ϕj), and the related function (ƒi) for i number of values. Different least-squares metrics quantify differences between predicted and observed values. The ordinary least squares (OLS)...
Typical Model Studies01:30

Typical Model Studies

Fluid mechanics model studies often utilize scaled-down systems to predict fluid behavior in full-scale environments, such as river flows, dam spillways, and structures interacting with open surfaces. Maintaining Froude number similarity in river models is crucial, as it replicates surface flow features like wave patterns and velocities.

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

ERS technical standard on reference values for cardiopulmonary exercise testing: summary report and a call for action.

The European respiratory journal·2026
Same author

European Respiratory Society/American Thoracic Society technical statement: standardisation of the measurement of lung volumes, 2023 update.

The European respiratory journal·2023
Same author

The Effect of Inspiratory Muscle Warm-Up on VO<sub>2</sub> Kinetics during Submaximal Rowing.

Sports (Basel, Switzerland)·2021
Same author

Maximal inspiratory pressure is influenced by intensity of the warm-up protocol.

Respiratory physiology & neurobiology·2016
Same author

Effect of inspiratory muscle warm-up on submaximal rowing performance.

Journal of strength and conditioning research·2014
Same author

Accuracy of some algorithms to determine the oscillometric mean arterial pressure: a theoretical study.

Blood pressure monitoring·2013

Related Experiment Video

Updated: Jul 10, 2026

A Two-interval Forced-choice Task for Multisensory Comparisons
07:13

A Two-interval Forced-choice Task for Multisensory Comparisons

Published on: November 9, 2018

Theoretical comparison between the model-based and amplitude-based compliance estimation techniques.

Jaak Talts1, Rein Raamat, Kersti Jagomägi

  • 1Department of Physiology, University of Tartu, Estonia. jaak.talts@ut.ee

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
|November 16, 2007
PubMed
Summary

Pulse pressure variation significantly impacts arterial compliance measurements. Model-based methods yield higher compliance than amplitude-based methods, especially at low transmural pressures, with increasing pulse pressure reducing amplitude-based estimates.

More Related Videos

A Psychophysics Paradigm for the Collection and Analysis of Similarity Judgments
08:12

A Psychophysics Paradigm for the Collection and Analysis of Similarity Judgments

Published on: March 1, 2022

Measuring Attention and Visual Processing Speed by Model-based Analysis of Temporal-order Judgments
13:00

Measuring Attention and Visual Processing Speed by Model-based Analysis of Temporal-order Judgments

Published on: January 23, 2017

Related Experiment Videos

Last Updated: Jul 10, 2026

A Two-interval Forced-choice Task for Multisensory Comparisons
07:13

A Two-interval Forced-choice Task for Multisensory Comparisons

Published on: November 9, 2018

A Psychophysics Paradigm for the Collection and Analysis of Similarity Judgments
08:12

A Psychophysics Paradigm for the Collection and Analysis of Similarity Judgments

Published on: March 1, 2022

Measuring Attention and Visual Processing Speed by Model-based Analysis of Temporal-order Judgments
13:00

Measuring Attention and Visual Processing Speed by Model-based Analysis of Temporal-order Judgments

Published on: January 23, 2017

Area of Science:

  • Cardiovascular Physiology
  • Biomedical Engineering
  • Medical Device Technology

Background:

  • Arterial compliance is a crucial cardiovascular parameter.
  • Accurate measurement of arterial compliance is vital for diagnosing and managing cardiovascular diseases.
  • Pulse pressure variation is a potential factor influencing arterial compliance estimations.

Purpose of the Study:

  • To theoretically investigate the effect of pulse pressure variation on arterial compliance measurements.
  • To compare model-based and amplitude-based compliance estimation techniques under varying pulse pressures.
  • To analyze the influence of arterial pressure-volume (P-V) relationship characteristics on compliance estimates.

Main Methods:

  • Utilized two asymmetric arctangent models to represent the arterial pressure-volume (P-V) relationship.
  • Applied both model-based and amplitude-based techniques for compliance estimation.
  • Conducted theoretical simulations to assess the impact of pulse pressure variation.

Main Results:

  • Model-based compliance values were systematically higher than amplitude-based values near zero transmural pressure.
  • Increasing pulse pressure amplitude led to a significant reduction in amplitude-based compliance estimates.
  • A less steep P-V relationship resulted in a smaller reduction in amplitude-based compliance with increasing transmural pressure.

Conclusions:

  • Pulse pressure variation is a critical factor that must be considered in arterial compliance measurements.
  • Amplitude-based compliance estimation is sensitive to pulse pressure amplitude, particularly at low transmural pressures.
  • The characteristics of the arterial pressure-volume relationship influence the accuracy and reliability of compliance measurements.