Comparative study of non-invasive blood pressure measurement methods in elderly people
Vratislav Fabian1, Martin Janouch, Lenka Novakova
1Czech Technical University in Prague, Faculty of Electrical Engineering, Department of Cybernetics, Technicka 2, Prague 6, Czech Republic. fabiav1@fel.cvut.cz
Abstract:
Results obtained by the modern automatic blood pressure (BP) monitors using oscillometric method [5] are highly dependent on conditions of cardiovascular system of the monitored person. Especially, with people who suffer from cardiovascular diseases (e.g. atherosclerosis) the resulting values differ significantly from those measured by the traditional auscultation method. A reasonable solution for improvement of quality of oscillometric method could be a sophisticated intelligent BP measuring system which applies for evaluation of BP more complex approach taking into account the monitored person's condition of patient cardiovascular system (CS) i.e. the hemodynamic parameters of CS (e.g. heart rate, stroke volume, total peripheral resistance, systemic arterial compliance, pulse wave velocity, augmentation index etc.). Such a system has to be based on appropriate models of the considered diseases which are validated on real life data. For that purpose, we have started to build a database of real-life oscillometric pulsations waveforms (OPW) complemented by the values of "auscultation" blood pressure measurements and additional relevant information about the considered patients (age, sex, etc.) as well as their diagnosis. This data collection requires a special HW device for measurement of the OPW--we have developed such a device and it has been validated in Czech Certified Metrological Centre. Our OPW monitor is connected through the T-pieces and tubes to the cuff, mercury sphygmomanometer and automatic "oscillometric" blood pressure monitor.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure