Cardiac output measurement in patients with an implanted pacemaker
Vlastimil Vondra1, Josef Halamek, Ivo Viscor
1Institute of Scientific Instruments, Academy of Sciences of the Czech Republic, Kralovopolska 147, 612 64 Brno, Czech Republic. vond@isibrno.cz
This study measured cardiac output in pacemaker patients using impedance cardiography. Optimal atrio-ventricular delay was identified to maximize cardiac output in 26 participants.
Area of Science:
- Cardiology
- Biomedical Engineering
Background:
- Pacemakers are commonly implanted to manage cardiac rhythm disorders.
- Optimizing pacemaker settings, specifically atrio-ventricular delay, is crucial for hemodynamic efficiency.
- Accurate measurement of cardiac output is essential for assessing cardiovascular function.
Purpose of the Study:
- To investigate the relationship between atrio-ventricular delay and cardiac output in patients with implanted pacemakers.
- To determine the optimal atrio-ventricular delay for maximizing cardiac output in this patient population.
- To present the findings from a cohort of 26 patients.
Main Methods:
- Utilized a custom-built digital bioimpedance monitor for impedance cardiography.
- Measured cardiac output in relation to varying atrio-ventricular delays.
- Calculated and scored the maximum relative cardiac output for each patient.
Main Results:
- Cardiac output was successfully measured in 26 patients with implanted pacemakers.
- The study identified specific atrio-ventricular delay settings that maximized cardiac output.
- Individualized optimization of atrio-ventricular delay demonstrated potential for hemodynamic improvement.
Conclusions:
- Impedance cardiography is a viable method for assessing cardiac output in pacemaker patients.
- Atrio-ventricular delay significantly influences cardiac output.
- Personalized optimization of pacemaker settings can enhance cardiovascular performance.
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...