Comparisons of FIR and IIR implementations of a subtraction-based stimulus artifact rejection algorithm

Meysam Azin1, Hillel J Chiel, Pedram Mohseni

  • 1Electrical Engineering and Computer Science Department, Case Western Reserve University, Cleveland, OH 44106, USA.

Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
Deconvolution01:20

Deconvolution

Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Impulse Response01:17

Impulse Response

The impulse response is the system's reaction to an input impulse. In an RC circuit, the voltage source is the input, and the capacitor's voltage is the output. The system's state and output response before and after input excitation are distinctly defined.
Kirchhoff's law forms an input signal equation, with the capacitor's current and voltage providing the output. Substituting the current and dividing by RC yields a differential equation. The output for an impulse input is the impulse...
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
Sum and Difference OpAmps01:22

Sum and Difference OpAmps

Operational amplifiers (op-amps) are versatile devices that extend beyond amplification. In this context, two specific op-amp configurations are explored: the summing and difference amplifiers.
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...
Fast Fourier Transform01:10

Fast Fourier Transform

The Fast Fourier Transform (FFT) is a computational algorithm designed to compute the Discrete Fourier Transform (DFT) efficiently. By breaking down the calculations into smaller, manageable sections, the FFT significantly reduces the computational complexity involved. Direct computation of an N-point DFT requires N2 complex multiplications, whereas the FFT algorithm needs only (N/2)log⁡2N multiplications, offering a much faster performance.