Multiplex Cytokine Profiling of Stimulated Mouse Splenocytes Using a Cytometric Bead-based Immunoassay Platform
Published on: November 9, 2017
Simultaneous detection of eight analytes in human serum by two commercially available platforms for multiplex
Gary Toedter1, Karen Hayden, Carrie Wagner
1Department of Clinical Pathology and Experimental Medicine, Centocor R&D, 145 King of Prussia Road, Radnor, PA 19087, USA. gtoedter@cntus.jnj.com
Abstract:
The accurate detection and quantitation of cytokines in serum are important in the study of disease mechanisms, pathogenesis, and treatment. Serum cytokines can reflect processes that are occurring at the cellular or tissue level and thus provide a means of indirectly monitoring these processes. Multiplex detection of cytokines allows the simultaneous measurement of multiple cytokines in a sample, increasing the efficiency of measuring the cytokines while reducing the serum sample volumes required for the testing. Two commercially available multiplex platforms were evaluated (Pierce SearchLight and Meso Scale Discovery), using multiplexes capable of simultaneously detecting eight cytokines. The cytokines analyzed in this study were gamma interferon, vascular endothelial growth factor, tumor necrosis factor alpha, interleukin-6 (IL-6), macrophage inflammatory protein 1beta, monocyte chemoattractant protein 1, IL-12p40, and IL-4. The range of quantitation of the platforms, the recovery of spiked cytokines, and the detection of the cytokines in serum samples from subjects with ulcerative colitis, Crohn's disease, rheumatoid arthritis, and psoriasis were examined. The findings showed that the detection of the cytokines was highly dependent upon the platform, with the consistency of the detection of cytokines across platforms being dependent upon the cytokine being analyzed. A careful examination of platform assay performance must be made prior to utilizing multiplex platforms in a study. While some cytokines will give similar patterns of results across platforms, others will be highly variable. The use of the same platform within a study or across studies where data will be compared is advised.
More Related Videos
09:43Microfluidic Approach to Resolve Simultaneous and Sequential Cytokine Secretion of Individual Polyfunctional Cells
Published on: March 8, 2024
06:37Using Reference Reagents to Confirm Robustness of Cytokine Release Assays for the Prediction of Monoclonal Antibody Safety
Published on: September 15, 2023