Related Experiment Video
Updated: Jul 10, 2026

Improved Hysteroscopic Resection of Endometrial Polyps Using 6-Fr Micro-Scissors and Forceps
Published on: August 2, 2024
Diagnostic accuracy of endometrial thickness to exclude polyps in women with postmenopausal bleeding
Anne Timmermans1, Maaike B E Gerritse, Brent C Opmeer
1Department of Perinatology and Gynecology, University Medical Centre Utrecht, 3508 AB Utrecht, POB 85090, The Netherlands.
Purpose:
To determine the accuracy of endometrial thickness measurement with transvaginal ultrasonography (TVUS) to diagnose endometrial polyps in women with postmenopausal bleeding in whom a carcinoma has been ruled out.
Methods:
In women with postmenopausal bleeding, endometrial thickness was measured with TVUS. If endometrial thickness was >4 mm, office hysteroscopy was performed. At hysteroscopy, the uterine cavity was assessed for the presence of polyps. Patients with malignancy were excluded. We used receiver operating characteristics (ROC) analysis to assess the capacity of TVUS endometrial thickness measurement to diagnose endometrial polyps. Findings at hysteroscopy were considered to be the reference standard.
Results:
We included 178 patients with postmenopausal bleeding and endometrial thickness >4 mm. Hysteroscopy showed an endometrial polyp in 90 patients (50%). The ROC analysis revealed that endometrial thickness had an area under the curve of 0.64 in the diagnosis of endometrial polyps.
Conclusion:
In women with postmenopausal bleeding in whom carcinoma has been ruled out, measurement of endometrial thickness with TVUS is not useful in the diagnosis of endometrial polyps.