Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Temperature measurements by coherent Rayleigh scattering
Optics Letters
|November 17, 2007
Summary
Coherent Rayleigh scattering (CRS) is now a viable method for measuring gas temperatures in low-density environments and plasmas. This technique accurately determines translational temperatures, showing potential for advanced gas diagnostics.
Area of Science:
- Plasma physics
- Laser-based diagnostics
- Spectroscopy
Background:
- Accurate temperature measurements are crucial for understanding plasma behavior.
- Existing methods may have limitations in low-density gases and weakly ionized plasmas.
- Coherent Rayleigh scattering (CRS) offers a potential non-intrusive diagnostic technique.
Purpose of the Study:
- To demonstrate the utility of coherent Rayleigh scattering (CRS) for temperature measurements in low-density gases and weakly ionized plasmas.
- To measure the translational temperature of neutral argon in a glow discharge using CRS.
- To investigate the applicable intensity range for Gaussian analysis in CRS temperature measurements.
Main Methods:
- Utilizing coherent Rayleigh scattering (CRS) to probe neutral argon in a glow discharge.
- Analyzing the spectral profile of the CRS signal.
- Applying Gaussian analysis to the spectral profile for temperature determination.
Main Results:
- Successfully measured the translational temperature of neutral argon.
- Achieved temperature measurements with an uncertainty of less than or equal to 3%.
- Determined the intensity range suitable for simple Gaussian analysis in CRS temperature measurements.
Conclusions:
- Coherent Rayleigh scattering (CRS) is a demonstrated, effective method for temperature measurements in challenging environments.
- The technique shows significant potential for future gas diagnostics applications.
- The Gaussian analysis of CRS signals provides accurate temperature data within a specific intensity range.
Related Concept Videos
Temperature Measurement Sites
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Atomic Spectroscopy: Effects of Temperature
Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...
Precipitation Gravimetry
Precipitation gravimetry is based on converting an analyte into a sparingly soluble precipitate, which is separated by filtration and weighed. An ideal precipitate should be pure, insoluble, of known composition, and easily filtered from the reaction mixture.
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Assessing Body Temperature - Temporal Artery
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Absorption of Radiation
The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation: