Related Experiment Video
Updated: Jul 10, 2026

Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
The effect of femoral component rotation on patellar tracking in total knee arthroplasty
Christian Luring1, Lars Perlick, Holger Bäthis
1Department of Orthopedic Surgery, University of Regensburg, Germany.
Abstract:
Rotational adjustment of the femoral component in total knee arthroplasty influences patellar tracking. Sixty patients underwent TKA; the femoral component was placed parallel to the epicondylar axis in 30 patients and the femoral component was placed in 3 degrees external rotation to the posterior condylar axis in 30 patients. The epicondylar axis was identified using an image-guided navigation system. Mean patellar shift was 2.65 degrees for the computer assisted group and 3.50 degrees for the control group. Mean patellar tilt was 4.88 degrees for the computer assisted group and 6.68 degrees for the control group. Aligning the femoral component parallel to the epicondylar axis leads to significantly better patellar tracking.
Related Concept Videos
Bones of the Lower Limb: Femur and Patella
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris group...